Heating and ventilation in milking parlours
Czech University of Life Sciences Prague, Faculty of Engineering, Kamycka 129, 16521 Prague 6, Czech Republic; *Correspondence: papez@tf.czu.cz
Abstract:
The aim of this paper is to show the results of the measurement of main microclimatic parameters (temperature and relative humidity) in milking parlours and compare the obtained results with values recommended in relevant standards. Temperature and relative humidity can affect animal welfare as well as the well-being of workers. These parameters were measured in three rotary milking parlours with herringbone type of stalls, each for 24 dairy cows. Two of these milking parlours were built in 2001 and one was built in 2009. Measurements were taken during the winter and summer periods, under extremely cold or high temperature conditions. Measurements were taken during the milking process for about two hours using suitable sensors for measurement of indoor temperature and relative humidity. The data of outside temperature and relative humidity were also obtained and compared with indoor data. The final results of the research were generalized. It is obvious from the results of measurements of selected milking parlours that heating and ventilation of milking parlours is insufficient. To set up adequate heating power, the heat balance of milking parlours was calculated. For adequate ventilation, the necessary flow of fresh air was calculated for both winter and summer periods. Also the methods of how to achieve these air flows are presented.
Key words:
measurement, relative humidity, temperature, THI.